Dyna-Glo RMC-KFA120T User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
12
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
(For RMC-KFA 210T Models Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove ignitor wire from spark plug.
- Remove spark plug from bracket-spark using medium
phillips screwdriver.
-
Clean and regap spark plug electrodes to 3.5mm gap.(0.138")
- ReInstall spark plug in bracket-spark.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
G.) PHOTOCELL
CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
(For RMC-KFA 45T/65T/120T/170T Models Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove photocell from it’s mounting.
Clean photocell lens with cotton swab.
TO REPLACE: Remove side cover near
on/off switch.
- Disconnect wires from circuit board and
remove photocell.
- Install new photocell and attach wires to
circuit board.
- Replace fan and upper shell.
Figure 16.
Figure 17.
Side cover
circuit board
Photocell
wires
Photocell
Install Photocell
1)Incorrect
2)Correct
Photocell
lens
(For RMC-KFA 210T Model Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove photocell from its mounting.
Clean photocell lens with cotton swab.
TO REPLACE : Remove side cover
opposite on/off switch.
- Disconnect wires from circuit board and
remove photocell.
- Install new photocell and attach wires to
circuit board.
- Replace fan and upper shell.
Figure 18.
Photocell
Install Photocell
1)Incorrect
2)Correct
Photocell
lens
circuit board
Side cover
Photocell
wires
Bracket Burner
Bracket Spark
Spark Plug
Gap
Ignitor wire
Page view 12